SBus Prestoserve
Sun-4/15/30/50/75 / SS4 / SS5 
SS10 / SS20 / SS600 / A11 / A12 / A14
Option 1021
 
 
Switch SW1
| SETTING | 
DESCRIPTION | 
 
| BAT | 
Enables battery backup mode | 
 
| 5V | 
Disables battery backup mode | 
 
 
Switch SW2
Press SW2 to determine the cache data state. 
| LED On | 
Cache data in memory | 
 
| LED Off | 
No cache data in memory | 
 
 
Power:
- 0.8 Amps @ +5Vdc
- 4.0 Watts
   
  
Software Compatibility
 
OPERATING SYSTEM | 
SBus PRESTOSERVE | 
 
| SunOS 4.1.1 | 
2.3 | 
 
| SunOS 4.1.2 | 
2.3 | 
 
| SunOS 4.1.3 | 
2.3 | 
 
| Solaris 2.1 | 
2.4 / 2.4.1 / 2.4.2 | 
 
| Solaris 2.2 | 
2.4 / 2.4.1 / 2.4.2 | 
 
| Solaris 2.3 | 
2.4 / 2.4.1 / 2.4.2 | 
 
| Solaris 2.4 | 
2.4 / 2.4.1 / 2.4.2 | 
 
| Solaris 2.5 | 
2.4.2 | 
 
| Solaris 2.5.1 | 
2.4.2 | 
 
| Solaris 2.6 | 
2.4.2 | 
 
| Solaris 7 | 
2.4.2 | 
 
 
Notes
- Set SW1 to BAT when the board is installed. Software will not
    initialize Prestoserve unless battery backup is enabled.
 - Set SW1 to +5V when the board is removed and cache data does not need
    saving.
 - Cache is cleared when SW1 is set to +5V for more than five minutes.
 - Do NOT accelerate the root file system.
 - Install Patch
    
 101714-01
    for Prestoserve 2.4 and 2.4.1, or
     103043-08
    for Prestoserve 2.4.2.
 - The Prestoserve hardware design is not compatible with 64-bit DVMA.
    Disable 64-bit DVMA when Prestoserve is used with Ultra 1 Model 170E,
    Ultra 2, and SunSwift. Refer to BugID 1224649. Add the following to
    /etc/system:
    
- set fas:fas_enable_sbus64 = 0
  
 - Only 32-bit drivers are provided by the Prestoserve software, so if
    you are running Solaris 7, you must boot in 32-bit mode for the
    Prestoserve drivers to load.
    See SRDB 18572.
  
References
 
  SBus Prestoserve User's Manual, 800-6396
 
  Prestoserve User's Guide, 801-4896.
 
 
 |