Sun Quad FastEthernet 1.0 (SQFE/S)
SS5 / SS10 / SS20 / SS600 / SS1000 / SC2000 
A11 / A12 / A14 
E3000 / E4000 / E5000 / E6000 
E3500 / E4500 / E5500 / E6500
Option 1042
 
 
Notes
- The minimum OS is Solaris 2.4 and Quad FastEthernet 1.0.
 - QFE/S 1.0 uses the SUNWhmed device driver.
 - QFE/S is not compatible with Sun Trunking 1.0.
 - The SS1000 and SC2000 require OBP 2.26.
 - One CPU per port is recommended for maximum throughput.
 - Two CPUs per QFE/S is recommended for >=200MHz systems.
 - SQFE <= 501-4302-03 fails the Fcode checksum test and will not
    configure during boot if the E3000-E6000 is set to Diagnostic mode.
    Set Keywitch diagnostics Off, OBP diag-switch? false,
    and OBP diag-level min.
 - Set the NVRAM variable local-mac-address? to true to enable the MAC
    addresses of the network interfaces on the Quad FastEthernet board.
  
Reference
 
  Sun Quad FastEthernet Installation Guide, 805-0732.
 
 
 |